Complete Guide to Gree AC Error Codes (With Solutions)

Gree ac error codes and solution

When your Gree air conditioner starts flashing error codes, it can be frustrating and confusing. As experienced HVAC technicians with over 15 years in the field, we’ve compiled this comprehensive guide to help you understand and resolve common Gree AC error codes quickly and effectively.

Understanding Gree AC Error Code Systems

Gree air conditioners use sophisticated diagnostic systems to communicate problems through LED flash patterns and display codes. Different models including Bora 28K, Bora 9/24K, Lomo Inverter, U-Match Fixed Speed, and U-Match Inverter systems each have their unique error reporting methods.

How to Read Gree AC Error Codes

Most Gree units display error codes through:

  • LED Flash Patterns: The indoor unit’s LED flashes a specific number of times
  • Digital Display: Direct error code display on the unit’s screen
  • Remote Control Display: Error codes shown on your AC remote.

 

The pattern typically involves 3 seconds OFF followed by the specific number of flashes corresponding to the error code.

Critical Error Codes Requiring Immediate Attention

E1 - High Pressure Protection

DetailDescription
What it meansThe system’s refrigerant pressure has exceeded safe operating limits.
Common causesDirty outdoor condenser coils, Blocked airflow, Overcharged refrigerant, Faulty pressure sensor
DIY SolutionsClean outdoor unit, Ensure 2–3 feet clearance, Clean air filters, Open all vents
When to call professionalsIf cleaning doesn’t resolve, refrigerant system diagnosis or sensor replacement is required.

E2 - Anti-Freeze Protection

DetailDescription
What it meansSystem detected potential freezing conditions in indoor coil.
Common causesDirty air filters, Low refrigerant, Blocked airflow, Faulty indoor temperature sensor
DIY SolutionsReplace/clean filters, Open all vents, Unblock return air grilles, Let system defrost 2–3 hrs
Professional diagnosis neededLikely refrigerant leaks or sensor issues.

E4 - Compressor Discharge Temperature Protection

DetailDescription
What it meansCompressor running too hot, triggering safety protection.
Common causesLow refrigerant, Dirty condenser coils, Faulty compressor, Restricted refrigerant flow
Immediate actionsTurn off unit, Check outdoor debris, Clean condenser coils, Restart after 30 min
Expert intervention requiredOften serious issues → refrigerant diagnosis needed.

Sensor-Related Error Codes (F Series)

F1 - Indoor Ambient Sensor Issues

SymptomsIncorrect readings, poor cooling/heating
Quick fixCheck loose connections
Professional solution

Sensor replacement & calibration

F2 - Indoor Coil Sensor Problems

SymptomsInconsistent operation, frequent cycling
CheckEnsure sensor isn’t damaged/iced
ResolutionUsually needs replacement

F3 - Outdoor Ambient Sensor Malfunction

ImpactPoor efficiency in extreme weather
Basic checkInspect sensor for damage/corrosion
FixReplacement & recalibration

F4 - Outdoor Coil Sensor Error

SignsInadequate defrost, reduced efficiency
ActionCheck wiring for damage
SolutionSensor replacement

F5 - Compressor Discharge Sensor Fault

Critical natureAffects compressor protection
Safety concernNever bypass this sensor
ResolutionImmediate professional service

System Protection Codes (H,U,E Series)

SymptomsDescription
H1 – Defrosting ModeSystem pauses cooling/heating temporarily; coil frost; resumes automatically after defrost.
H3 – Compressor Overload ProtectionAC shuts down suddenly, trips frequently, poor cooling/heating; caused by poor ventilation or compressor stress.
H6 – Indoor Fan Motor MalfunctionNo airflow, weak airflow, or strange noises; results in poor cooling/heating, incorrect room temperature readings.
P5 – Compressor Over Current ProtectionSudden shutdown, breaker trips, buzzing sound; poor cooling due to electrical overload.
PH – High DC Voltage / PL – Low DC VoltageAC won’t start or shuts down unexpectedly; incorrect display readings, unstable cooling/heating.
U7 – Reversing Valve MalfunctionAC stuck in cooling or heating mode only; room fails to reach desired temperature.
E6 – Indoor/Outdoor Communication ErrorAC unresponsive, shows error code, fails to start; incorrect temperature readings, no cooling/heating.

Free Tips to Prevent Gree Error Codes

Monthly Maintenance

  • Clean or replace air filters
  • Check for blocked vents and grilles
  • Inspect outdoor unit for debris
  • Verify thermostat settings

Seasonal Maintenance

  • Professional coil cleaning
  • Refrigerant level inspection
  • Electrical connection tightening
  • Sensor calibration check

Annual Professional Service

    • Complete system inspection
    • Preventive maintenance program
    • Performance optimization
    • Safety system verification

When DIY Solutions Don't Work

If you’ve tried the basic troubleshooting steps and error codes persist, it’s time for professional intervention. Continuing to operate a malfunctioning AC can lead to:

  • Compressor damage
  • Electrical system failure
  • Increased energy costs
  • Complete system breakdown
  • Safety hazards

Get Our Professional Gree AC Repair Services

At Maqsood and Sons Islamabad, we specialize in comprehensive Gree AC repair and maintenance services. Our certified technicians have extensive experience with all Gree models and error codes.

Our Services Include:

  • Emergency Repair Services: Available 24/7 for critical breakdowns
  • Preventive Maintenance Programs: Keep your system running efficiently
  • Refrigerant System Diagnosis: Professional leak detection and repair
  • Electrical System Repair: Safe handling of all electrical components
  • Sensor Replacement and Calibration: Precision temperature control restoration
  • Compressor Repair and Replacement: Expert handling of major components

Why Choose Our Professional Services:

  • Certified Technicians: Factory-trained on Gree systems
  • Genuine Parts: Only authentic Gree replacement components
  • Warranty Protection: All repairs backed by comprehensive warranties
  • Rapid Response: Same-day service available in Islamabad area
  • Transparent Pricing: No hidden fees, upfront cost estimates

Get Our Professional Gree AC Repair Services

For professional technicians working on Gree systems, understanding proper refrigerant pressures is crucial. Different refrigerant types (R22, R134a, R410A) have specific pressure requirements at various temperatures. Always refer to manufacturer specifications and use proper gauges for accurate diagnosis.

Understanding Gree AC error codes empowers you to perform basic troubleshooting and know when professional help is needed. While some issues can be resolved with simple maintenance, many error codes indicate complex problems requiring expert diagnosis and repair.

Remember, safety should always be your priority. When in doubt, especially with electrical or refrigerant-related errors, contact qualified professionals. Regular maintenance and prompt attention to error codes will keep your Gree AC system running efficiently for years to come.

Don’t let AC problems disrupt your comfort. Contact Maqsood and Sons today for reliable, professional Gree AC repair services in Islamabad.