Dawlance AC Error Codes List with Expert Solutions ( Maqsood and Sons Islamabad )

Dawlence ac error codes and solution

When your Dawalance air conditioner displays an error code, instead of panicking the first thing you should do is check out its error and note it down. As certified AC repair technicians with over 15 years of experience servicing Dawalance units across Islamabad and Rawalpindi, we’ve made this comprehensive guide to help you understand and resolve these error codes quickly and effectively. 

About Our Expertise: As being official sales partner of Dawalance Islamabad, we’ve repaired over 3,000+ Dawalance AC units, making us one of the most experienced Dawalance service providers in the twin cities. Our lead CEO Muhammad Maqsood, is a certified HVAC specialist with manufacturer training from multiple brands. For more information about our projects and about our company you can visit our website or social handles.

Understanding Dawlance AC Error Codes: What They Really Mean

Dawlance inverter and conventional AC units use alphanumeric error codes to indicate specific malfunctions. These codes appear on your indoor unit’s display and serve as diagnostic tools that help identify problems before they cause permanent damage to your AC system.

Why Error Codes Matter:

  • Prevent costly component damage
  • Enable quick troubleshooting
  • Help determine if DIY fixes are possible
  • Indicate when professional service is required

Critical Dawlance Protection Error Codes

E1 - Indoor Room Temperature Sensor Error

DetailDescription
What it meansIndoor room temperature sensor is malfunctioning or has loose connections.
SymptomsAC doesn’t respond to set temperature, continuous running, erratic cooling patterns.
DIY SolutionsRestart AC after 10 mins, check sensor placement, avoid sunlight/heat sources, clean dust near sensor.
When to call professionalsIf issue persists, sensor replacement required.

E2 - Indoor Coil Temperature Sensor Error

DetailDescription
What it meansEvaporator coil temperature sensor is faulty/damaged.
Common causesWire damage, corrosion, defect, wear (5–7 yrs).
SolutionsPower cycle unit, check wire damage, clean coil area.
Professional repairSensor replacement requires technician expertise.

 

E3 - Outdoor Coil Temperature Sensor Error

DetailDescription
What it meansOutdoor coil sensor fault or wiring issue.
TroubleshootingInspect outdoor unit, check ventilation, ensure 2 ft clearance, clean outdoor coil.
Expert tipCommon in extreme summer heat; providing shade reduces occurrences.

E4 - Indoor Unit Fan Motor Error

DetailDescription
What it meansIndoor fan motor malfunctioning or blocked.
Immediate actionsTurn off AC, check for obstructions, listen for unusual noises, inspect fan blades.
Safety warningNever touch fan blades while powered.

E5 - Communication Error Between Units

DetailDescription
What it meansIndoor/outdoor unit communication breakdown.
Common causes (Pakistan)Power fluctuations, loose wires, interference, PCB malfunction.
SolutionsCheck connections, use voltage stabilizer, restart with stable power, inspect comm. cable.

System Protection Codes

P1 - High Voltage Protection

DetailDescription
What it meansAC detected dangerously high voltage → shut down.
Pakistan-specific fixInstall voltage stabilizer (common issue).
Immediate stepsCheck voltage, avoid peak hours, add surge protection, consider dedicated power line.

P2 - High Discharge Temperature Protection

DetailDescription
What it meansCompressor discharge temp too high (overheating).
Common causesDirty filters, blocked coil, low refrigerant, overworked compressor.
SolutionsReplace filters, clean outdoor coil, check refrigerant, ensure airflow.

 

EC - Compressor Overload Protection

DetailDescription
What it meansCompressor overloaded → protection triggered.
Critical actionsTurn off AC, allow 30 min cooldown, check airflow, verify refrigerant levels.
When to worryFrequent recurrence → possible compressor failure.

Communication and Display Errors

E6 - Outdoor Fan Motor Error

DetailDescription
What it meansOutdoor fan motor failed or blocked.
DiagnosisInspect fan, check free blade movement (when off), wiring check, listen for humming motor.

E8 - Communication Fault Between Display & PCB

DetailDescription
What it meansDisplay board not communicating with main PCB.
TroubleshootingCheck connections, restart system, check ribbon cables, verify display power.

 

Advanced Error Codes

F0 - Outdoor Unit Protection Error

DetailDescription
What it meansGeneral outdoor unit protection triggered.
ChecksPower supply, overheating, refrigerant lines, electrical faults.

Others F Series Errors

F1 – Outdoor Module ProtectionOutdoor control module detected abnormal condition.
F2 – Power Factor Correction ErrorPower supply quality issue affecting AC’s power management.
F3 – Compressor Start FailureCompressor failed to start within expected time.

Dawlance AC Error Codes Frequency Analysis

Based on our service data at Maqsood and Sons Islamabad:

 

Error Code

Frequency

Typical Cause

Repair Cost Range

E1

35%

Sensor failure

PKR 2,500 – 4,000

E3

20%

Outdoor sensor

PKR 3,000 – 5,000

E5

15%

Communication

PKR 4,000 – 8,000

P2

12%

Overheating

PKR 1,500 – 6,000

EC

8%

Compressor issues

PKR 8,000 – 25,000

Others

10%

Various

PKR 2,000 – 10,000

 

Emergency Troubleshooting Tips for Common Scenarios

Scenario 1: AC Shows E1 and Won’t Cool

Immediate steps:

  1. Check if curtains or heat sources are near the indoor sensor
  2. Clean the area around the temperature sensor
  3. Reset the AC and monitor for 30 minutes
  4. If error persists, schedule sensor replacement

Scenario 2: Multiple Error Codes Appearing

This indicates serious issues:

  1. Turn off the AC immediately
  2. Check the main power supply
  3. Inspect for water damage or electrical issues
  4. Contact professional service immediately

Scenario 3: Error Code Appears During High Usage

Peak load problems:

  1. Reduce the temperature setting by 2-3 degrees
  2. Ensure all windows and doors are closed
  3. Check if multiple ACs are running on the same circuit
  4. Monitor power consumption

Why Choose Maqsood and Sons for Dawlance AC Service

  • 15+ years of specialized AC repair experience
  • Certified technicians trained on Dawlance systems
  • 3,000+ successful Dawlance AC repairs completed
  • Same-day service available in Islamabad and Rawalpindi
  • Genuine parts guarantee with warranty

Expert Tips from our 15 Years of Experience

Pro Tips for Dawlance AC Owners

Daily Operation:

  1. Never set temperature below 22°C for energy efficiency
  2. Use auto mode for optimal performance
  3. Keep indoor units dust-free for sensor accuracy
  4. Maintain logbook of any unusual behavior

Weekly Maintenance:

  1. Visual inspection of both units
  2. Check remote control functionality
  3. Listen for unusual noises
  4. Monitor electricity consumption patterns

Monthly Care:

  1. Thorough filter cleaning
  2. Outdoor unit clearance check
  3. Drainage system inspection
  4. Performance evaluation

Red Flags That Require Immediate Attention

Call us immediately if you notice:

  • Burning smell from any unit
  • Water leakage inside the house
  • Electrical sparks or crackling sounds
  • Ice formation on refrigerant lines
  • Dramatically increased electricity bills